I emailed Ideal how provided incorrect advice that it was the air pressure sensor - I have definitely proved this is not the case.
I suspected the PCB and spoke to a company who refurbish PCB's. They say the key failure of the PCB is the fan relay. I have some blackening on one set of...
I have been working through the fault finding guide. The fan does not start if I remove the stat, as Ideal say it would. They then ask for the supplies to the pressure switch to be checked, looking for power on the violet and red leads - which I have. The fault finding guide then just says...
Hi,