Recent content by ChrisPriest

  1. C

    Potterton Performa 28 Problem

    Scratch that.... It's now working! Perhaps I did get some water somewhere it wasn't supposed to be, the flame failure light did keep coming on with attempts to light the boiler, however after a few attempts, she stayed lit. I'm guessing I did get something wet. Will keep an eye on it and...
  2. C

    Potterton Performa 28 Problem

    Possible, I've checked the PCB for signs of water, removed it and checked underside as well but no sign... Guess I'll have to go and get another PCB and see if that cures the problem :)
  3. C

    Potterton Performa 28 Problem

    Hi Mick, Have increased pressure to near 1.5bar on the CH, but still no joy, flame failure light still flashing. Tried to reset by holding selector to the left for 2-3 seconds, but same old thing :( Thanks for the tip tho :) Cheers Chris
  4. C

    Potterton Performa 28 Problem

    Hi All, Wondering if someone might be able to shed some light on this: Got a Potterton Performa 28 that 2 days ago stopped heating hot water, discovered that the diaphram had perished and was not pushing the pin out to engage the DHW microswitch. Drained system, shut off water and...