Recent content by chudsy

  1. C

    Decisions Decisions.......

    I know !! Bad question to ask thinking about it :wink: Cheers Paul.
  2. C

    Decisions Decisions.......

    Hi All, Our ususal plumber has recommended the Baxi Avanta as and upgrade for our ancient Ideal boiler, but my work colleague's son who is also in the trade would go with a similar sized W-Bosch. There's basically nothing in price difference but the Baxi has the longer warranty. Any...
  3. C

    Hotpoint WDD960G Filter?????

    Rocks, you are a god of these machines. Run a full cycle and all is well. Many thanks for your advice. I can now re-comission it back to the wife :D Cheers again. Paul.
  4. C

    Hotpoint WDD960G Filter?????

    on a test run now. time to clear up the tools and have a beer :D fingers crossed!!!
  5. C

    Hotpoint WDD960G Filter?????

    Right then, I hopefully think it's 'happy days' !!! I checked on a rinse cycle and was getting a 240 feed to the drain motor. As the motor was already out I plugged that in and it fired up on the floor so fingers crossed the problem is solved. I did take the multi plug off the board and give...
  6. C

    Hotpoint WDD960G Filter?????

    sorry rocks, just one more question. Will the controller error mode if I pull the connector off the motor and plug my meter in or do I have to have the motor in the circuit? My background is mobility products and as soon as you start creating open circuits the controllers will error...
  7. C

    Hotpoint WDD960G Filter?????

    so should I just put it on a drain cycle and see if any power kicks in at the pump terminals? Many thanks Paul. PS - why are you in the maldives, you'd make a killing over here with your knowledge :D
  8. C

    Hotpoint WDD960G Filter?????

    Thanks Rocks, Pulled the filter out and there was a pleasant surprise, 2 x £1 coins, a button and some plastic packing!!!!!!! I made an error with the motor. I just bought a new one but realised that my meter wouldn't beep out on continuity as there's about 160 ohms in the coil and both are...
  9. C

    Hotpoint WDD960G Filter?????

    Is that the rubber conical ribbed part? Thanks, Paul.
  10. C

    Hotpoint WDD960G Filter?????

    Update, no continuity on the pump terminals so I guess that's goosed!!! Looke easy enough to replace tho! Regards Paul.
  11. C

    Hotpoint WDD960G Filter?????

    Hi, Removed the white back cover and can't see any signs of a filter, just the small pump and a direct line into the plastic case. I've cleaned the terminals wil electrolube and will try again. Is there definately a filter on these things? Regards, Paul.
  12. C

    Hotpoint WDD960G Filter?????

    Nice one, cheers for the info. The wife says it's intermittent at the moment so hopefull it'll be poor connections as it's 3 years old. Regards, Paul.
  13. C

    Hotpoint WDD960G Filter?????

    Hi, Our machine has started to display the F11 code which would indicate that the filter would need a check. I've taken off the bottom front cover and where the user manual says the filter should be is a red cover with a warning logo on. Any ideas anyone?? Regards, Paul.
  14. C

    Could X800 overkill damage pump?

    Cheers Andy, Managed to drain off about half the system tonight before having to refill and turn the heat back on. Will hopefully drop the system on the weekend and add inhibitor. Paul.
  15. C

    Could X800 overkill damage pump?

    xmas and young family and cold weather so i had to take a day off work to drop the system so the heating could go off. I'll get to it straight away. Cheers
Back