    Glow-worm Micron 70FF Domestic boiler

    I changed the parts one at a time after each consultation. The first fault was when the boiler tripped and would not reset. After changing the recommended parts the Air Control Switch was the problem. Both engineers said it could not be this and by using the manufacturers fault test it tested...
  2. C

    Glow-worm Micron 70FF Domestic boiler

    I changed the boiler parts because no heating engineers were available because of the adverse weather conditions. I consulted with two heating engineers by telephone who both gave me the same remedies. By 'tripping out' means the boiler stopped firing up and went into 'Reset Required'. After...
  3. C

    Glow-worm Micron 70FF Domestic boiler

    I have a Glow-Worm Micron 70FF domestic boiler which trips out every 2-4 days. I have replaced the Electrode, Thermistor, Circuit Board(PCB), Safety Temperature Limiter, Fan and Air Pressure Switch, but the tripping continues. The only thing left to replace is the Gas Control Valve. Any ideas...