Recent content by David cooper

  1. David cooper

    no floods or explosions, yet !

    no floods or explosions, yet !
  2. David cooper

    CM707 with Hive, will it work? (Rick's thread)

    I'm still waiting until some hacker geek type computer spotter brings out a scanner thingy that turns on everybody's heating on the hottest day of the summer !
  3. David cooper

    F&E tank overflowing. why ? Oh why ?

    Update, problem solved ! I replaced the gas valve & set the burner pressure to 10 m/b (old one was set at 14 m/b. Now everything is behaving great. ( customer phoned me 3 days after to confirm) Thinking about this, I reckon that although everything is behaving, there must be a partial blockage...
  4. David cooper

    F&E tank overflowing. why ? Oh why ?

    It doesn't pump over all the time (it was doing that before I raised the open vent) Secondly, no other alterations have been done to the system before this problem started. Just got home from work. Friday is always airlock city! Some nice slew are now calming me down
  5. David cooper

    F&E tank overflowing. why ? Oh why ?

    Update. Ordered & fitted a new boilerstat on tuesday .(Using heatsink compound) Got the phone call next day to say F&E tank still dripping when heating is running. Went back yesterday, pump is on c/h return. Was on speed 3 & hadn't been touched before problem started, put it down to speed 2...
  6. David cooper

    F&E tank overflowing. why ? Oh why ?

    I'm going back tomorrow morning to cap the f&e cold supply . Can't seal the system as no overheat thermostat fitted. Customer is not bleeding rads every week, pump is existing one. I may combine cold feed & open vent. Perhaps I should get a priest in to exercise the system ! Will keep you...
  7. David cooper

    F&E tank overflowing. why ? Oh why ?

    Thanks for the quick replies gents. It's 100% the f&e overflowing as it's drowning the float !! System filled up a dream. will check the pump speed but it shouldn't do it anyway. System is at least 30 years old.
  8. David cooper

    F&E tank overflowing. why ? Oh why ?

    Please help me, I am admitting failure here.Customer's F&E tank was overflowing when heating was on. Very old ballvalve, so I replaced it as it dripped every 8 seconds or so. got a phone call next day. Problem still there so as main cold water tank is higher than F&E tank i suspected the...
  9. David cooper

    Gledhill boilermate 2000, what can I replace it with ??

    Who makes them ? Is it the same company that makes the torrent ? Thanks for the post.
  10. David cooper

    Gledhill boilermate 2000, what can I replace it with ??

    Went to look at job today & an unvented it will be with open vent system. Thanks for the advice.
  11. David cooper

    Gledhill boilermate 2000, what can I replace it with ??

    Don't want to seal system as 3 storey house with plastic pipework 14 years old & whole estate is a leak timebomb ! I don't like condense or D2 pumps where I can get away without one as something else that can fail.
  12. David cooper

    Gledhill boilermate 2000, what can I replace it with ??

    Can't see how I'm going to run the TPR discharge pipe. Has anyone had any experience with a torrent thermal store? I know I would have to fit an f&e tank though.
  13. David cooper

    Gledhill boilermate 2000, what can I replace it with ??

    Got a customer with a 2000, he wants a cylinder with an immersion fitted. Any ideas please. Boiler is suprima & I know I'll have to run a pump live. Thanks.
  14. David cooper

    Gas valve change profile 80 41-590-53. Will it fit ?

    Found 2 of them in my spares (probably from when I worked for British Gas (rip off company) for 18 years) !! Part no 907702 . pretty sure new ones on eBay.
  15. David cooper

    Gas valve change profile 80 41-590-53. Will it fit ?

    OK, I am gas safe registered & have applied for the combustion chamber. Thanks