Recent content by DazzarGaz

  1. D

    commercial kitchen gas upgrade help

    Hi there, I've a bit of an obvious question but it doesn't seem to have been covered by the various comments so far. What is actually there at the moment? From what I've seen, you have a takeaway with 200KW of appliances, no safety equipement and all hanging off a U6 meter. Has the...
  2. D

    Error Code Keston Boiler

    I just been to look at one of these today. Checked the error code history and E.80 popped up. The boiler was acting very strangely. The spark ignition was constantly sparking and the pcb was detecting a flame current of 4.8 micro amps even though the gas was turned off. Spoke to Keston to...
  3. D

    Worcester 26CDi losing pressure can not find leak.what next?

    Is it possible to leave the CH isolated for several hours to see if the system pressure drops?. You really need to identify if it's a boiler leak or a rad/system leak.
  4. D

    Unvented Cylinder heated from Combi?

    Sorry DP. I'll have to write that other awful name in full in future. Is he still lurking around here?
  5. D

    F&E Tank height above Radiator level

    After seeing the contents of some cylinders and CWST's I think a bit of x100 in your shampoo might be a healthier option! :D
  6. D

    F&E Tank height above Radiator level

    The cold water storage tank should be above the level of the F&E tank. This is to prevent possible contamination of hot water if there is a pin hole leak of the cylinder coil.
  7. D

    Unvented Cylinder heated from Combi?

    Use the Alert button. Don't feed the Troll.
  8. D

    Unvented Cylinder heated from Combi?

    Shock Horror!! Has Dickpuller returned?. Has he assimailated Agile?. Or......is Dickpuller the alter ego of Agile?!!! AAAAAAAAAArrrrrrrrrrrrrrrrrrrggggggggggggghhhhhhhhh!!!!
  9. D

    newly fitted flat panel radiator cold

    I hope you haven't got cream carpets! It's best to use an aquavac to suck the water from the rad (40 quid from wickes) or else crack open one of the valves and put a bowl under it. Use the bled screw to control the amount of water coming out. Can be a very messy job. If it's a tall rad say...
  10. D

    Boiler Books

    Get the Corgi book and be very familiar with it's contents. This is the book you tend to use in the ACS exams.
  11. D

    boiler in garage

    A plume kit is not designed nor approved for going through a roof. that is what a vertical flue kit is designed for.
  12. D

    Radiator Troubles

    If you turn off all the rads that are working, this will force the hot water into the ones that are suspect. If they heat up nicely then you've got a balancing problem.
  13. D

    Curved radiators

    Just note that they are pretty heavy and difficult to man handle and mount on a wall due to their offset centre of gravity.
  14. D

    Radiator Troubles

    Sounds like the system needs to be balanced. There should be the required info in the FAQ for balancing rads. Daz