Recent content by DJ_DIY

  1. DJ_DIY

    UFH - what electrics does UFH need - 2 setups.

    Well the floor has been levelled ready for UFH, and with the new extension/kitchen layout there aren't enough walls to hang radiators on to properly heat the room. It is North facing (unfortunately) . As the builders didn't lay the concrete floor remotely level I had to add a few (42) bags of...
  2. DJ_DIY

    UFH - what electrics does UFH need - 2 setups.

    Hi I have an Grant oil boiler. Gravity fed HW. Single zone C-plan, no actuators, one pump, heating system. Two tanks in loft. immersion on first floor. HIVE hw/ch wireless controlled with receiver next to boiler. The wiring is very simple and all components are in the boiler cupboard in...
  3. DJ_DIY

    Concrete floor and DPC height changes

    Hi @noseall Weather looks good so im going to have a go at this tomorrow. Can you confirm the following please: Cut the radon and DPM Knock out the inner course of blocks along the whole bifold area. Add sand across cavity concrete and under removed blocks Flatten and rejoin radon barrier...
  4. DJ_DIY

    Concrete floor and DPC height changes

    Didnt think so. I wanted to use sand and cement render. I cant take any photos at the moment as its all covered up with a dpm sheet so my house doesn't flood. The vertical insulation should be level with the top of concrete though? WUNDA UFH provide their own thermal bridge for the perimeter...
  5. DJ_DIY

    Just how bad is this?

    Had a carpenter round last night to look at the flat roof. He was also less than impressed. Said he would have to work on the steel to get it flat and fill in all the empty mortar joints before putting the timber against the house. Him and the brickie are hopefully going to take both steels...
  6. DJ_DIY

    Concrete floor and DPC height changes

    Hi Sorry about asking another question. This time it's to do with the concrete floor. The extension was to have the following make up for the floor: 150mm Type 1 Blinding sand Radon Barrier 100mm Celotex DPM 100mm Concrete 20mm UFH 10mm Self levelling 4mm vinyl The top level of the concrete...
  7. DJ_DIY

    Just how bad is this?

    Would any you be willing to pay 5+ man days for "supply and installation of steel"? BC say the steel is structurally sound. Not sure how the wall above it isn't considered.
  8. DJ_DIY

    Just how bad is this?

    Ah the choc block !! That was me, I had to quickly split the cable while they were working. Its only for the "kitchen" light which will be replaced when the sparkie can actually start work.
  9. DJ_DIY

    Just how bad is this?

    I had to, they were about to start block work above DPC. The white cables were on sale in the 70's I believe.
  10. DJ_DIY

    Just how bad is this?

    not sure if DIYNOT will let me do this, but heres a link to a video
  11. DJ_DIY

    Just how bad is this?

    The builders who started my extension have left the steel like the pictures below. Initially they installed the two steels together so the inner skin only sat on less 20mm of the steel. When I asked why i was given the old "That will be ok, it aint going nowhere". The joists were sat in the...
  12. DJ_DIY

    Radon Barrier, DPC, and DPM. Is this right?

    Hi I thought about cutting, joining and adjusting radon so in the wall nibs to the side of the bifolds it was as the first part of this thread, but under the bi folds it goes horizontally across the filled in cavity.... But securing the bifolds to the floor would mean putting concrete screws...
  13. DJ_DIY

    Radon Barrier, DPC, and DPM. Is this right?

    Is there a way i can fill in the cavity infront of the bifolds so the floor goes to the external skin? Thanks
  14. DJ_DIY

    Radon Barrier, DPC, and DPM. Is this right?

    thats my point in a round about way..... Radon barrier is essential for a house in a radon area, and must be through both skins or BC wont sign it off. The other sides, ah we won't worry about them. I'll seal/stick the radon barrier to the existing walls just above concrete. Thanks
  15. DJ_DIY

    Radon Barrier, DPC, and DPM. Is this right?

    under the plasterboard then OK thanks ill check out Celotex Thermaclass Cavity Wall 21 Ok thanks. WIll be a pain folding at least one of my internal corners. I can understand the idea of a radon barrier. All good when the room has 4 external sides like a tiny house, lol. When two sides are...