Recent content by Donatella

  1. D

    Worcester Bosch 24cdi new pcb

    hello, Any expert out there that can advise what link I need to get the internal thermostat working? Thanks
  2. D

    Worcester Bosch 24cdi

    Strange behaviour from boiler, hot water works perfectly fine and modulates. Heating comes on fine the first time according to temperature set, but once the it auto-turns off after reaching desired temperature, even though the CH light remains on, the ignition does not start again even after the...
  3. D

    Worcester Bosch 24cdi RSF

    Just checked the water HE is brand new original changed about 2 months ago.
  4. D

    Worcester Bosch 24cdi RSF

    Thanks for the response. Yes the central heating radiators are working but what I also notice is that it burner is either in on or off state when CH is on the desired temperature, it runs for longer if temperature is set high. For example if I have CH on lowest temperature setting, it runs for...
  5. D

    Worcester Bosch 24cdi RSF

    Hello, Domestic hot water always comes out very hot regardless of the temperature setting on dial. Boiler fires up and then switches off (flames out) after about a minute and then comes back on again as the water begin to cool down. Believe this is called short cycling - Hot water flow is...
  6. D

    Worcester Bosch 24Cdi : removing PRV + weeping from diverter

    how did you get it out at the end? : )
Back