    Horstmann E7BX hot water controller

    Yes. I am still trying to find out what the times should be to ensure I put on dishwasher and washing machine on at the correct time overnight.
  2. E

    Horstmann E7BX hot water controller

    Electricity supplier came this morning (turned up 75 minutes late). They said everything is wired correctly and they said (as JohnD did above) that I am probably getting more cheap electricity than I should be.
  3. E

    Horstmann E7BX hot water controller

    Thanks to everyone for your help
  4. E

    Horstmann E7BX hot water controller

    Not at home. I've found a picture of a similar on the internet (apologies to the copyright holder for posting it here without permission). Min are in better condition than the one in the picture. There are two dials. One input and one output. At the moment I have the input on level 3 so...
  5. E

    Horstmann E7BX hot water controller

    The indicator neon come son 22.30 to 08.00 so these are not the off-peal times as told by my supplier. I checked my meter readings last night. At 22.30 they were Rate 1: 56, Rate 2: 9, Rate 3: 420. This morning they are Rate 1: 57, Rate 2: 10 and Rate 3: 447.
  6. E

    Horstmann E7BX hot water controller

    Yes bills are high this is why I started complaining again this year. They said I was on correct tariff as I use all my elec at night. I said that's because immersion heater is on all night. Just been on Rtis website and it says I am getting a weak long wave signal here due to problems with...
  7. E

    Horstmann E7BX hot water controller

    Electricity company are coming again next week. Problem is they have already changed the meter ( a couple of weeks ago) so they say that can't be the problem.
  8. E

    Horstmann E7BX hot water controller

    Yes if I turn off the storage heater box and turn on the boost timer the light on the e7bx comes on . There's a cable left hand top of e7bx which goes behind the board and I think then going up to the main fuse box. Earlier I said this wire was going to the immersion but now i think it's going...
  9. E

    Horstmann E7BX hot water controller

    Tail 5 does go to mem cu
  10. E

    Horstmann E7BX hot water controller

    See above night time, afternoon for 2 hours and day time rates
  11. E

    Horstmann E7BX hot water controller

    Out of e7bx one ca.ble to the box which controls night storage heaters other I thin to immersion. I know the night storage heaters are on but I can't tell what times they are storing the heat. I've stil got them on as I live near benson which is coldest place in England still frosty most mornings
  12. E

    Horstmann E7BX hot water controller

    Pictures of wiring, immersion and the meter which has 3 rates
  13. E

    Horstmann E7BX hot water controller

    So there is a timer inside the e7bx which somehow Set itself to come on at 2230 and go off at 0800 despite the fact it has never been touched since installed when I moved in 12 years ago and worked correctly for several years
  14. E

    Horstmann E7BX hot water controller

    Not sure if I can get any more in the picture due to door on the pantry cupboard but I'll try later. I can't tell whether the night storage heaters are on - they're very old. I haven't recently moved in - I 've been in the property about 12 years. This problem first occurred 6 years ago and...