  1. E

    Potterton SUPRIMA 40L won’t turn on, trips RCD immediately :(

    Thanks very much for advice Harry and Elkato. I’ll leave it as it is for now. I don’t think it was working anyway like you say, as the time to get the hot water is the same to me. Makes sense. It prob failed a while ago and I didn’t even notice until water got into the cabling of the pump and...
  2. E

    Potterton SUPRIMA 40L won’t turn on, trips RCD immediately :(

    Thanks. It was indeed the circulator pump that had a slight leak. The cable coming out of the black part of the pump was disconnected from the control box on the wall and the boiler came on with tripping the rcd. I was told that pump only really helped woth the hot water coming out the tap...
  3. E

    Potterton SUPRIMA 40L won’t turn on, trips RCD immediately :(

    Could it have anything to do with this? I haven’t noticed any leaks but the line scale there would say otherwise. Also that black box on the side with the cable going to (controller box?) looks to have a little water around the point of the red arrow. That cream box isn’t used anymore really...
  4. E

    Potterton SUPRIMA 40L won’t turn on, trips RCD immediately :(

    Hi My Potterton Myson SUPRIMA 40L appears to have a problem. At first it was running for a while then it tripped the RCD. I wasn’t able to see if it was a call to heat or not. Now the next day when I’ve tried to turn it on (using a fuse switch nearby to the hive controller) it immediately...