ericmark's latest activity

  • ericmark
    ericmark reacted to IJWS15's post in the thread Hive wiring queries with Thanks Thanks.
    Jusr rewired the wiring centre in line with diagram above with adjustments due to wiring centre being in the landing cupboard and...
  • ericmark
    ericmark replied to the thread Awkward Downlights.
    Question one has to be, are the lights fitted with bulbs? Seems daft, I know, but some lamps are integral units, and you can't change...
    • 1766499007167.png
  • ericmark
    OK may be unusual as my flat under main house, not used that much, and used in the main by my daughter when she stops over, and she may...
    • Lampandremote.jpg
    • G9-comp.jpg
  • ericmark
    Mine does, Bodelwyddan is not that far way, Tayna Batteries was Manchester Batteries in Abergele but seems taken over and moved twice...
    • 1766496076522.png
    • 1766496504459.png
  • ericmark
    This is a smart bulb, not yet fitted, where is the FCC ID? Since it says RGB it is clearly a smart bulb, since new also have the packet...
    • 1766495027551.png
    • Smart bulb GU10 packet.jpg
  • ericmark
    ericmark replied to the thread What size and make of boiler ?.
    My boiler 20 kW also 5 bedrooms, and it is ample. But I have TRV's on all radiators, 10 with electronic heads, 4 still with mechanical...
  • ericmark
    ericmark replied to the thread Hive wiring queries.
    The Y Plan is an odd system, to stop DHW heating it needs power, and often we see where the off wires are missing. With the old boilers...
  • ericmark
    ericmark reacted to flameport's post in the thread Hive wiring queries with Like Like.
    Probably been wired wrong for years or even since it was installed. If someone has been tempering in the past, it's always quicker to...
  • ericmark
    ericmark replied to the thread Hive wiring queries.
    I have worked out, in summer, cheaper to use the immersion heater, at least with my house. In winter, I have no option, but my DHW will...
  • ericmark
    Every lock has a by-pass, so the water from the horse-shoe falls on the dee, is taken to Cheshire. Having walked there, it was not...
    • 1766431891868.png
    • 1766432017397.png
  • ericmark
    The refrigeration plant can be split into at least three different types, the commercial plant, often the motor varies speed to control...
    • 1766430839423.png
  • ericmark
    The 2.5 hours is not simply times by 650 watt which my tumble drier uses, as it depends on the load, with a light load, it uses a...
    • 1766427654233.png
  • ericmark
    ericmark replied to the thread Hive wiring queries.
    With the Y Plan, the DHW only does not power or move the motorised valve, The red line shows the DHW connection to give us DHW when we...
    • 1766426752550.png
  • ericmark
    In the past, been surprised how little it costs to wash clothes, it is the drying which costs, your £10 per year will mean just a few p...
  • ericmark
    ericmark reacted to Rodders53's post in the thread How to do washing using off-peak? with Thanks Thanks.
    FWIW my Miele TwinDos washer is "smart" and has a 'report' that says we've done 16 cycles this month... 5.5 kWh in total and 342 litres...
Back