    ericmark replied to the thread Ancient wiring problems..
    I had the same situation, I knew the house built 1954 was bad, but dad said "I am not living in a building site. You can re-wire it when...
  • ericmark
    The TRV can connect to a sensor, so can measure the temperature remote to the TRV head, but you can also have a display, the problem...
    • 1769252142549.png
    • 1769252357307.png
    • 84067_P.jpg
  • ericmark
    No my Wiser TRV head can do the lot, it all depends on what head is put on the TRV as to what it can do,
  • ericmark
    Even the cheap eQ-3 TRV heads can be paired, so all radiators work together. In 2019 when I fitted them cost me £15 each for the heads.
  • ericmark
    What one needs to remember is a TRV is a thermostat, it depends on where one reads as to if it needs a timing element, but the...
    • EVO-home1.jpg
    • 1769250949398.png
    • 1769251217343.png
  • ericmark
    Yes, if I was starting again would be all Wiser TRV heads.
  • ericmark
    ericmark replied to the thread Hot water far too hot.
    I also have no tank thermostat which connects to the central heating, the only way to set DHW cooler is to also have the CH water...
    • C-Plan_old.jpg
    • 1769190756617.png
    • C-Plan.jpg
    • C-Plan_old2.jpg
  • ericmark
    ericmark reacted to Justin Passing's post in the thread Central heating with Like Like.
    @markg71 never said he had any TRV's. We don't know what boiler or controls he has. So most of the above is conjecture, or not helping...
  • ericmark
    One would assume the system was designed rather than thrown together 27 years ago, so why is there now a problem? I had the same, and...
  • ericmark
    Even if you had all the heads marked, it's not a simple yes or no, in real terms suck it and see. Even the direction of filler pipe can...
  • ericmark
    Well put @Harry Bloomfield I did look at cheaper mechanical TRV heads. The ones I removed, when tested, had about 3°C between fully...
  • ericmark
    Perhaps Eric has the 'one' TRV, where the room temperature needs to be closely maintained at the correct temperature, rather than...
  • ericmark
    ericmark replied to the thread 80A PME Fuse.
    I did say that, only once have I needed to look at the let through current, where the loop impedance was too low, decided to fit a 20...
  • ericmark
    Because I have not paid for TRV heads which link to a hub. I got 5 of these, and had 4 of these taken from my late mothers house, the...
    • EQ-3 Bluetooth Smart Radiator Thermostat.jpg
    • IMGP8035.jpg
    • 1769179263291.png
    • 1769179303956.png
  • ericmark