    ericmark replied to the thread Electric boiler?.
    No, this is my point, fill a bath, and looking at fuel cost, but if you need 1 pint of hot water, and to get it you need to run off 4...
    • Torrent pipe example.PNG
  • ericmark
    People are always getting upset with me, but quick look at you and so seems most people like your posts.
    • 1769709259608.png
  • ericmark
    ericmark replied to the thread Electric boiler?.
    Yes, I would agree. But I would say CH and DHW are two completely different things. CH yes gas or oil, as any attempt to store and...
    • 1769703346220.png
  • ericmark
    ericmark replied to the thread Neutral-Earth Voltage 120V.
    I find moving the device I can see how close or far away the cables are. Not really what the voltage is.
  • ericmark
    ericmark replied to the thread Flickering LED Tape.
    I used this and it has worked fine. The strip is clearly designed to dim, but the TCP has only one white temperature, left, plus colour...
    • 1769700015310.png
    • 1769701010727.png
    • 1769702174770.png
  • ericmark
    ericmark replied to the thread Neutral-Earth Voltage 120V.
    With new ones yes, not back in 1980 when I first came across them. I found the cheap stick type does not have a graded response. Both...
    • 1769699181217.png
  • ericmark
    ericmark replied to the thread Neutral-Earth Voltage 120V.
    I did show my NCV tester, it is part of the clamp-on meter, where the two jaws meet, so not really going to help using fingers.
  • ericmark
    ericmark replied to the thread Ceiling Rose Headache.
    I have counted three browns, and two blues, so it seems a blue is missing. I would guess the missing blue would be over sleeved with...
    • 1769696726930.png
  • ericmark
    ericmark replied to the thread Neutral-Earth Voltage 120V.
    I note the new breed, but seems it needs batteries the hole idea was a tester which could not be turned off, or fail due to depleted...
    • Diffrence line neutral 8 Feb 24 reduced.jpg
    • 1769696278595.png
    • 1769695517561.png
    • 1769694835538.png
    • 1769693328445.png
    • 1769693171493.png
  • ericmark
    Not official been given it yet, it will be my birthday present. So not got the instructions out of the box. So did a google...
    • 1769662164397.png
    • 1769662186424.png
  • ericmark
    ericmark replied to the thread Setting up a new TV?.
    I have just found the bit on the TV so it will switch on with the Sky box, On the TV Inputs HDMI CEC needed clicking on.
  • ericmark
    Thank you, @mattylad seems I got it wrong I assume "installed" means plugged in? But it does mean a TV set and a monitor and computer...
  • ericmark
    You've had the benefit of my advice when you had equipment issues previously, here and on another forum. I even offered to call in on...
  • ericmark
    As @JohnD says, proving dead is a long-winded process for items one can't unplug, and likely most of us don't follow the process to the...
    • Diffrence line neutral 8 Feb 24 reduced.jpg
  • ericmark
    ericmark replied to the thread Neutral-Earth Voltage 120V.
    I have worked on a Robin tunnel boring machine which had delta 3 phase 220 volt, with no earth reference, and it is not something I want...