ericmark's latest activity

  • ericmark
    Mine is oil, C Plan, and near impossible to measure how much oil used, but we use to need two deliveries per year, now down to one...
  • ericmark
    I have found the same, non modulating 20 kW boiler, will run for 20 minutes, before it starts cycling off-on, set the timer for ½ hour a...
    • Saved last 28 days Tuesday 4th Aug 26.jpg
    • 1791552625025.png
    • 1791553375092.png
  • ericmark
    Electricity Prices from 1st May 2026 Standing charge (per day) 69.699p Unit rate - day (per kWh) 32.277p Unit rate - night (per kWh)...
  • ericmark
    I have had VOIP phones, and also used Whatsapp, and each seems to have some good and bad points, the main thing seems to be the ability...
  • ericmark
    ericmark replied to the thread EV charger output voltage.??.
    It is only a switching and monitoring device, little more than a socket, so no voltage change, the V2G EV charging point is designed for...
  • ericmark
    ericmark replied to the thread Rewire or not?.
    found here so socket needs to be 300 mm from the corner. As to fitting a consumer unit then testing, I agree an electrician should...
  • ericmark
    I have a cheap one which shows if cable OK, and one which measures current, but find of little use as it seems down to both cable and...
  • ericmark
    ericmark replied to the thread Ryobi Combi Drill choice ?.
    I think we all have thoughts as to what drill to buy. My problem is Parkside items are not always on sale, so when I needed a new hedge...
    • 1791507298964.png
  • ericmark
    ericmark replied to the thread Rewire or not?.
    13th edition (Issued in 1955) only allowed no earth if the lighting fittings using filament lamps installed in a room having a...
  • ericmark
    ericmark replied to the thread Rewire or not?.
    An EICR requires the inspector to do a lot of work, which is not required if the result is a re-wire. I only really needed to remove...
  • ericmark
    ericmark replied to the thread Rewire or not?.
    Many council houses near where I lived were wired with metal conduit which took the earth to the light switches. I would say, select...
  • ericmark
    ericmark replied to the thread Rewire or not?.
    As @pete01 says, but dates don't match, 1966 the rules changed, so built 1969 there should have been earths to the lights, even before...
    • VC60B.jpg
  • ericmark
    Very true, we tend to just consider our own homes, looking at my own I already use 4.4 kW overnight at cheap rate, add 7 kW to that and...
    • 1791451722890.png
    • 1791452013005.png
  • ericmark
    I was talking about oil filled no fuelled, the oil stores some of the heat, so although the heater is switching on/off with a mark/space...
  • ericmark
    I would guess by-pass valve stuck open, but not down to you to play with, contact landlord.