ETAF's latest activity

  • ETAF
    ETAF replied to the thread Help Please!.
    do you feel confidant that you can remove the front of the sockets/fused connection and pull out slightly and look at the wiring inside...
  • ETAF
    ETAF replied to the thread Help Please!.
    when you do get up tomorrow and start to look at the problem again - JUST a suggestion - re-read all the posts here from the start and...
  • ETAF
    ETAF replied to the thread Help Please!.
    Ok, was part of the previous post as well , explaining you picture wait till morning , when light - I'm in UK and will be around...
  • ETAF
    ETAF reacted to sparkwright's post in the thread Help Please! with Thanks Thanks.
    Have you loosened any of the socket fronts off the wall to do your diagram? If so, were there any loose wires? I'm NOT suggesting you...
  • ETAF
    ETAF replied to the thread Help Please!.
    on the consumer unit - as asked before which MCB turned OFF the kitchen you have a B32 MCB labelled sockets (maybe a RING main ) and a...
  • ETAF
    ETAF replied to the thread Help Please!.
    it should likely be a RING - a Radial its often thicker wire than i think i saw , not great photo of wire - ring 2.5mm radial maybe...
  • ETAF
    ETAF replied to the thread Help Please!.
    and the last socket on the right does NOT have a wire coming out to somewhere else ?? just 1 wire in - OR maybe the out wire goes in...
  • ETAF
    ETAF replied to the thread Help Please!.
    so the ticks mean working - correct ?
  • ETAF
    ETAF replied to the thread Help Please!.
    yep, as also asked a while back OR also
  • ETAF
    ETAF replied to the thread Help Please!.
    as mentioned , when you do change the fuse - if that fixes the issue then you have other issues with the wiring AND was working before...
  • ETAF
    ETAF replied to the thread Help Please!.
    well , really should not be as if it is on a RING main then even if they have wired the ring split with the fuse, then if fuse blows -...
  • ETAF
    ETAF replied to the thread Help Please!.
    so which switch was that - as you have sockets written on both sides of CU and that stopped all the sockets off that where ON - Green...
  • ETAF
    ETAF replied to the thread Help Please!.
    as mentioned
  • ETAF
    ETAF replied to the thread Help Please!.
    as mentioned in other post assuming the labelilng is correct - MOST UNLIKELY given the amount of MCBs so maybe well off here CU picture
  • ETAF
    ETAF replied to the thread Help Please!.
    is the fridge plugged into one of the working sockets and working NOW everything in the house all sockets are working except for the 3...
Back