    Central heating issues???

    Quick update, I've redone the downstairs with the plastic 22mm flow and return with 15mm feeds to the radiators.. Good news, the heating system works a charm now. Loads of black sludge came out the old pipework and was even in the new pipework I just had put in last summer... it's now as clean...
  2. F

    Central heating issues???

    Haha yah dilalio I know but I've tried to get a straight answer and I've just been running round in circles. Had a few quotes from plumbers and it was between £400 and £750 just to get my downstairs pipes replaced. Some people said it needed to have 22mm flow and return and others (cheaper...
  3. F

    Central heating issues???

    Yeh they were but after the boiler got moved they didn't, problem was that I got the boiler moved last summer, so didn't find out the radiators wouldn't work until winter came and by then I was busy taking them off the walls (so didn't think too much about them not working) so I could skim and...
  4. F

    Central heating issues???

    That's the problem, downstairs radiators don't work. One one radiator warms up a little in the bottom corner next to the TRV but all other downstair radiatorsare cold. Currently the flow and return feeding the radiators are 22mm steel/copper mixed pipe (from the 60s I think). So I've got 22mm...
  5. F

    Central heating issues???

    Hi So got a quick question for the plumbers out there, I've recently had my 28kw boiler moved from my bathroom upstairs to my kitchen downstairs and the heating pipes that ran up the wall were replaced. They were 22mm copper to 15mm plastic. I'm a little worried tho.... I checked tonight and I...
  6. F

    Doorbell transformer

    So basically I need a modern transducer and the bell should work fine? Sorry this is all new to me. And yeh it's a little on the old side, the wire that was being used just snapped when I tried to bend them to reach the fastening screws.
  7. F

    Doorbell transformer

  8. Untitled

    Untitled

  9. Untitled

    Untitled

  10. Untitled

    Untitled

  11. Untitled

    Untitled

  12. Bell transformer

    Bell transformer

  13. F

    Doorbell transformer

    Thanks ericmark I will have a look on the transducer tomorrow and see if it has either of those signs on it. If it does will it be a simple case of fitting a 3pin plug? Thanks for the quick help.
  14. F

    Doorbell transformer

    Hello, I was hopeing someone maybe able to help me out here. My sister recently had her new house fitted with a new fuse box. Upon fitting the new fuse box the electrician removed the old doorbell because it wasn't earthed. Now this is a lovely old bell and I would like to try and get it up and...
  15. F

    I broke the loo :-( *twin trap*

    Don't wanna replace the W/C because it matches the rest of the bathroom, I've ordered a Dudley turbo 88 with a aspirator bomb. Anyone tried to fit one of these?