  1. G

    honeywell galaxy g2-44

    Thats as may be, but the solution is there now for anyone else with the same problem to see.
  2. G

    galaxy engineer code

    remove mains remove battery put a link between 0v and tamper on the siren out pins on the pcb remove connections to zone 1 (1001) defeat panel tamper switch, put the end station panel screw in place then power the panel up bay battery first then mains enter default code 1234...
  3. G

    honeywell galaxy g2-44

    remove mains remove battery put a link between 0v and tamper on the siren out pins on the pcb remove connections to zone 1 (1001) defeat panel tamper switch, put the end station panel screw in place then power the panel up bay battery first then mains enter default code 1234...