Recent content by Gasplumber

  1. G

    Electric Showers

    My mistake then. I must of only seen the Mira sports then! Mira sports is on the left. Last time I seen one anyway that’s why I started avoiding Mira as thought they was left feed only
  2. G

    Fitting a new shower arm

    Never seen that before but cut/break off the washers and metal behind the nut maybe it’s a push fit type grab ring. If that doesn’t release it your gonna need a plumber. The pictures ain the best focused to be honest
  3. G

    Electric Showers

    Be carful with Mira the inlet is on the left. my go to is triton easy fit. As it’s one that I know is very universal. Not best quality ect but does the job
  4. G

    When should copper pipes be replaced?

    Only replace if you was doing a refurb in your forever house
  5. G

    Leak on compression fitting on ch flow pipe from boiler

    There’s an olive yes. When I have a leaking compression I try to tighten it. then next would be jointing compound, if there was still a problem a few wraps of ptfe would fix it. If that didn’t work which is unlikely! I’d be thinking the pipes cracked in the fitting or summat like that
  6. G

    Leak on compression fitting on ch flow pipe from boiler

    Obviously boiler off and cold pipes
  7. G

    Leak on compression fitting on ch flow pipe from boiler

    The method I said takes balls! As long as you hold the pipe in to the fitting you could do what I said. I say hold it as if it’s in loose pipework it can pop out
  8. G

    Worcester Greenstar 25i repressurise issue.

    Get it serviced and they will show you. Your condense will prob be blocked next year then it won’t work. Think emergency breakdown!
  9. G

    Honeywell CM927 Starting to Fail.

    agreed Honeywell display issues on the cm’s is shocking. Hardwired is the future, or is it supposed to be the past haha
  10. G

    Leak on compression fitting on ch flow pipe from boiler

    Tighten it some more. If that doesn’t help undo the nut on the side that’s leaking with a towel handy to catch water then get some ptfe or jointing compound and slide the nut off the fitting whilst you hold the pipe pushed in to the fitting and apply paste or ptfe. Then retighten.
  11. G

    Does It Really Matter Who Installs Your Boiler ?

    Just ask to see the gas safe registered I’d and ask if they’re insured. A lot of companies can charge £1000s more. Your Best against what I just said is approaching a gas engineer who works for a firm but does private jobs ;)
  12. G

    Air Lock in Water System

    Yes that’s correct possibly too although unlikely as it’s his mom in a flat. The usual suspect of the random airlocks is the ballcock Obviously tank sizing can play a part but it’s not the norm. In the same way maybe the main passed through the downstairs flat and they’re doing work and keep...
  13. G

    Fitting external expansion vessel.

    for such a smart guy you should know how to fit a external vessel!
  14. G

    Possible asbestos flue

    Yep there’s not much else it could be to be fair. best practise is as above but spray water on it before removal! Obviously too late now!