Recent content by Gaspt

  1. G

    ideal isar with random lf fault

    Spark gen , they are a common fault on these
  2. G

    Video - Whats up with this Ideal Classic - clicking?

    Sounds like its cutting the power to the fan when it makes the noise, this means its not the gas valve because if it was the fan would still be running, the problem u have could be pcb or the demand dropping out then coming back, the potentiometer causes this fault on these boilers
  3. G

    Worcester Combi Boiler/Radiator Problems - Drayton Digistat

    The relay in your receiver is not switching over, this is a common fault with these stats, I'm afraid you will need to replace it, I would change it for a Honeywell cm921
  4. G

    Droning noise in central heating boiler

    In my opinion the problem you have is a blocked up noisy hex, when you had your expansion vessel fit the system was drained dragging dirt into it, if you put noise reducer in your system the noise will go, or you could get it powerflushed,(the reason it is noisy when you run water is because it...