Recent content by Gavinoneill

  1. G

    Wall mounted boiler frame not flush with wall at top

    To add to this.. I fit around 120-150 Worcester boilers a year. All products have some form of metal wall jig/frame that is fixed with between 6 and 12 screws. I prefer to use 10x2's or 10x3's. If the jig is installed on to lat and plaster 12 screws would be used, if this fixing doesn't go to...
  2. G

    Wall mounted boiler frame not flush with wall at top

    I wouldn't advise doing any kind diy work on or around the boiler. "Is the boiler safe" that is impossible for me to make a judgment on as I haven't made an inspection of the appliance. If you feel the appliance is putting life and property at risk then the only two courses of action are 1...
  3. G

    Wall mounted boiler frame not flush with wall at top

    Worcester only allow pipes up the back of the boiler within the wall jig on far left and right, and only in certain places lower down under the expansion vessel. The reason for this is two fold, one to enable removal of the expansion vessel and two so the pipes don't obstruct the prv. The reason...