Recent content by glasgowman

  1. G

    no heating hot water

    Hi thats what i thought it was to was a fast blow fuse...cant see it been anything else...
  2. G

    no heating hot water

    sorry worchester bosch 24i junor se combi
  3. G

    Hi mate wondering if you good help me ?

    Hi mate wondering if you good help me ?
  4. G

    no heating hot water

    no heating no hot water...power to boiler but mechanical clock not make any sound..was working earlier this evening..i was trying to fit a wireless programmable room stat...How ever silly me forgot to un plug the clock from the board..I'm think i have blown a fuse on the pcb...any sugesstions ???
  5. G

    reinstated fire - tightness test before?????

    Hi there, You are right you are allowded a (4mbar) drop over 2mim,but experenices allways tells you that a tightness test confirms gas is sound before anywork is carried out there for shouls there be a fault with appliance you can inform the resonpbile person of the proplem and adviuce...
  6. G

    Who is responsible for the gas pressure to the meter?

    The Gas transporter deleivers the gas to the meter at 75 mbar..then the governour or regulator deleivers 21mbar to all appliances regardleess. Domestic gas meters supply 6m3 gas eater per hour thats it...If you have more than one appliance or maybe 2 and the new appliance is in the same...
  7. G

    Wireless reciever cont

    Vokera compact HE Went to an old customer house tonite to fit a wirelss reciever to above boiler ok..try out wirelees reciever on my own boiler a worcherster junior and know proplem at all. Have checked wiring digram for boiler in bookelt..it shows only external time clock with volt free...
  8. G

    Wireless reciever

    I have done it another way..guys.. Netural to Netural Com - Ls No - Lr link out and its working
  9. G

    Wireless reciever

    hi there. I will tell you how i have installed reciever. On the boiler you have left to right control board Live,Netural,Space,Ns,Ls,Ns,Ls,Lr,Fv...Link in Ls and Lr taken out correct so far? Celect Thermsave DRF 3 wiring diagram on reciever as follows...1,2,3,4,5 blocks...Netrual (1)...
  10. G

    Wireless reciever

    Hi thanks for reply to my message.. any suggestion mate?
  11. G

    Wireless reciever

    I have a Worchester Bosch 24i junior combi boiler with a built in clock for heating great. Phoned Worchester about fitting a external wireless reciever with programme stat,They had told me that as long as it was 240v free there would not be a propelm. I have bought a celect Thermsave DRF3...
Back
Top