Recent content by hammo2809

  1. H

    Why can I not replace a light bulb? 4pin PLTs

    Stay away from supermarkets and DIY stores if you looking to buy replacement bulbs such as these. I always use my local electrical wholesalers. Better quality of bulb and if there is a problem they have the expertise to advise.
  2. H

    Wylex NHS12SL

    simple answers is yes, the nhxb mcb's are the correct ones for your boaed. However if you want the board to installed to the current 17th edition regs you will need to fit some rcbo's in the board. Or exchange the board you have for the Wylex nhsr10sslhi, then fit the nhxb mcb to comply with the...
  3. H

    JCC Fireguard downlights advice

    JCC is a good choice for downlighters, they are a very reliable fitting. I would recommend the KSR LED (KSRLP855) retro fit lamps which fit these fittings. They come in 4.5Watt non dimmable and 4.9Watt dimmable. The dimmable option is always good for the dining area to create different mood...