Recent content by happyman1010

  1. H

    RSJ TO RAFTERS HELP

    just so any readers know the rsj is a uc 203/203/60 and seven mts over a six mt opening cheers rob
  2. H

    RSJ TO RAFTERS HELP

    Hi all had some great help of tony 1851 and jeds when i ask rsj help so rsj size is sorted have a lean to conservatory, with a tile roof running at 18 deg question about rafters to rs j now trying to save a bit of high can i bolt a timber beam to the web of the rsj and fit the rafters...
  3. H

    rsj help

    that's very true, and thanks to all you guys for helping me, clearly the SE i used went way over the top on his vaules so the beams were too much!!!! anyway all sorted and thanks again
  4. H

    rsj help

    hi well just a safty margin. working on figures of yours and mine tiles 0.1 batton 0.01 felt 0.01 raf 0.2 cel 0.15 mine say 0.35 which looks high 0.47 if i stick with 0.75 LL mine 0.6 would give me 1.22 total so your right moving to 1.35 is a safety margin
  5. H

    rsj help

    hi guys just a double check if i use LL 0.75 DL 1 useing a uc 254/254/73, x-x vaule of 11407 i get a deflection of 3.45mm am i right ?
  6. H

    rsj help

    well thanks guys looks like i need to get a set of SE calculations look a bit over the top the set i have using a LL 0.75 and a DL 0.47 with what i have but take it up to 0.85 instead of the 1.27 he used
  7. H

    rsj help

    ah forgot about that divide by two plus its light weight tiles only 9.47kg sq mt think thats 0.1 kn
  8. H

    rsj help

    well looking at some SE calculations its done by calculation and thats where the prob is vaules a high 1.27 DL AND 0.6 LL
  9. H

    rsj help

    are you using 0.0063*1.6*6^3/2348?
  10. H

    rsj help

    from his calculations, just testing i am reading the formula right rob
  11. H

    rsj help

    hi am i being thick but using the formula just making sure i read it right ? for uc 203/203/52 0.0063*1.87*6^3/5259 im getting 0.0004838745 must be doing something wrong ? steel tables say 5259 but what about area of roof? ie 24 sq mts come in to this ?
  12. H

    rsj help

    thought so, when i looked at the values did tell him at the time what i was using, but now he passed away
  13. H

    rsj help

    they weigh 630grams and approx 13 to the sq mt
  14. H

    rsj help

    ah but i found some called envirotile interlocking roof tile and they are 9,47 kg sq mt, thanks for all your help
  15. H

    rsj help

    yes your right on the plasterboard 0.35 is high but the tiles are 9,47kg sq mt his calculation is 0.7 how much does that improve the deflection?
Back