Recent content by hawnit

  1. hawnit

    Electric shower valve failure

    there was a small black diaphragm (intact) and spring in the upper part, yes. they fell out when i took the valve assembly out of the unit to investigate/photograph. I have had this happen twice - exactly the same and same time of day/weather (even same day of the week thinking about it!) , each...
  2. hawnit

    Electric shower valve failure

    thanks so much for your help!
  3. hawnit

    Electric shower valve failure

    This is how the valve assembly broke - it seems like this plug should have been glued in but adhesive failed. Just poor-quality component or component pushed beyond capacity?
  4. hawnit

    Electric shower valve failure

    Thanks, Johntheo5. I have the Triton T80 Easifit+ which is a mains-fed system. Thinking about it, occasionally in the past the pipework to this unit seems to have had an airlock or blockage or something - low pressure alert on and won't power on. (This is a rarely used spare bathroom shower)...
  5. hawnit

    Electric shower valve failure

    Hi, I have had 2 Triton T80 Electric showers, and on both the solenoid valve assembly housing (the plastic part of the valve) has completely broken in two at random moments when not in use over the last 3 years. Both times has been during periods of hot weather. The break in the housing is very...
Back