Recent content by jacqueline23

  1. J

    new baxi sssure 524 coming on when room thermostat not calling for heat

    no not that..turns out the room thermostat needed to be rebinded to the boiler programmer paired basically .found the instructions .niw back to how was..
  2. J

    new baxi sssure 524 coming on when room thermostat not calling for heat

    baxi assure 524 boiler coming on without room thermostat calling fir it to . room thermostat set 16 room temperature 20 boiler coming on no flame symbol on room thermostat honeywell dt92e ,boiler programmer st9120c flame symbol on mode is continuous , is the room thermostat not...
  3. J

    Baxi assure 524 boiler and sundial rf2 pack 1 room thermistat

    it is definitely running 30 secs off then 3 mins pump over run..I'm checking it again listening and documenting times on off etc..a sparky was here Friday with the gas repairs supervisor the sparky got involved with the thermostat and tried something that he thought wud help but it just altered...
  4. J

    Baxi assure 524 boiler and sundial rf2 pack 1 room thermistat

    I'm looking at the page abd currently I'm looking thinking..crikey can't get my head round hiw to change it..its not very clear gir me how to do it..could anyone explain it to me step by step ..nit very good at these things.. but thankyou fir helping...when the council git the boiler they only...
  5. J

    Baxi assure 524 boiler and sundial rf2 pack 1 room thermistat

    hi yes it is a DT92E R/T WITH The ST9120C programmer.. sounds helpful if someone can tell me how to do that.....
  6. J

    Baxi assure 524 boiler and sundial rf2 pack 1 room thermistat

    it's a honeywell sundial rf2 pack 1 and boiler is baxi assure combi 524 ..
  7. J

    Baxi assure 524 boiler and sundial rf2 pack 1 room thermistat

    and it's a brand new boiler and thermostat fitted 30 aug , I'm a council tenant and everyone seems foxed as to whether it's normal to do this or not..its maintaining the temperature that the room thermostats is set to very well but is it normal to come on for just 30 seconds and go off and...
  8. J

    Baxi assure 524 boiler and sundial rf2 pack 1 room thermistat

    could you try answering this for me please. i have new boiler and room thermostat , ive seen on someposts that it is usual that .when you set room thermostat say to 20° it is correct for boiler to ignite even at 20° as a smaller drop than 0.5 degrees is registered and boiler is maintaining rooms...