i thought i had
basically the stat requires the link (which is a perm live also to the receiver)??? unlike a normal prog room sat that does not??? is that correct? :oops:
I get it now!! Thanks so much for helping me here guys, I really am greatful!
I guess I should've bought a wireless stat/receiver which was all of 240v then i'd only have needed 3 wires!
Anyway I get it now and will get the wiring done tonight :)
It's good to know why you are doing...
Hi mrgas
i do get it (sort of)!
in the past i have only wired up normal room stats and a prog room stat, hence my confusion here :oops:
Basically, with my boiler, for a normal PROG ROOM STAT: i would need 3 core from the boiler to the prog room stat (or 2 if no neutral was...
ok thanks for explaining that. i really appreciate you helping me understand how the receiver/stat works.
you're gonna flip at me :( but can i ask another question (which'll probably sound daft to you) :oops: :
if the receiver is volt free, then why do you need the additional 240v...
is water flow at other mains water taps ok?
if the electric is ok and no rcd has tripped/fuse blown, etc then it ma be a faulty solenoid valve inside the unit...
take the showerhead/hose off and see if water flows then...
Thanks for explaining mogget, really appreciate it.
How comes a wireless receiver for some reason needs another live to it (to make the switch) whereas if i ran a 3 core to a prog room stat i wouldn't need that extra live??... (ie the link)??
ok thanks for explaining that.
so basically, unlike a normal standard programmable room stat (which requires 3 core from the boiler to the prog room stat), the wireless receiver requires an extra live supply to it to the switch, thus the link from the L to the A terminal??
Thanks for your reply.
I will wire as you have stated, but I am not sure why it is this way (it is confusing me)! :cry:
I understand how a programmable room thermostat or a programmer and a standard room thermostat can be wired to the worcester 28i junior, but with the wireless room stat's...
The reason why the BNP got so many votes (and UKIP to a degree) is because they are the ONLY party that openly ADMITS what many people are thinking/feeling about the immigration problems. It is too much and getting out of hand.
It is all well and good for Labour/Conservative members to spout...
Hope someone can help :)
I have a combi (it is worcester 28i junior)
Theres no time clock and room thermostat - so no control over the heating. the water side is fine.
Nothing at all here for htg though :(
I would like to install a HONEYWELL CM900 wireless room stat / receiver.
The...