Recent content by jasramsden

  1. J

    Just doesn't look right!!!!

    Brilliant, just what I needed to hear. Thanks mate, Jas
  2. J

    Just doesn't look right!!!!

    Evening all, We had our boiler replaced a few months back as the old one was just knackered. The old system was replaced for a Worcester Bosch boiler which I am really happy with and the plumber stripped out all the old pipe work and tanks in the loft. In general, everything seems fine apart...
  3. J

    Underfloor insulation

    Hi all, I will be replacing my downstairs boards on a suspended timber floor and I would like to know if anyone has any experience in insulating under the boards before I lay them down. I was considering stapling chicken wire or similar to the underside of the joist and then filing in with...
  4. J

    Single to dual pipe system

    Yes, auto by pass sounds about right. Basically, what happens if all the radiators where turned off and the boiler was on? It's a combi boiler and I have a mix of valves, most are thermostatic. Also, what's your take on flexible pipe? It's going to be a nightmare pulling up the floor...
  5. J

    Single to dual pipe system

    I'm planning to change upstairs first and then a month or so later will be changing downstairs.
  6. J

    Single to dual pipe system

    Thanks Terry, Is there any balancing required at all or can it the pipes just be chopped and re-routed (quickest way back of couse). Do I need a pressure relief valve between the flow and return?
  7. J

    Single to dual pipe system

    Hi Alec, The rads at the far end of the run never get hot, and since I have most of the down stairs ceiling down, I can see one run that goes round the side of the house (about 12m) until it gets to the master bedroom rad. Also heard that F&R systems are a lot more efficient. Radiators...
  8. J

    Single to dual pipe system

    Hi, I have a single pipe system that I need to change to a twin as the upstairs rad just don't get anything at the far end of the house. I am just in the process of ripping down the downstairs ceiling and wondered if it would be easier to do the following as the upstairs boards are 2 by 8...
  9. J

    Single pipe system upgrade

    Hi ya, I have a condensing boiler and a single pipe system. Not sure why they didn't upgrade the to a twin pipe system but there you go. I am doing various bits around the house including a new celinig downstairs and a new floor downstairs. The upstairs flooring are 2 by 8 sheets and they...
Back
Top