Recent content by JCBeds

  1. J

    Holes

    ColJack, My last house was a new build (D/Wilson) and the build quality Crap with only the roof tiles not needing any snagging work doing. I now have extended a 1920`s 2up 2down adding 60sm on the side and back. I have already batterned out the old 9" solid brickwalls for adding celotex and...
  2. J

    Holes

    Thank you everyone for your help. :wink: All I want now is for a Chelsea win this afternoon....... Cheers, JC
  3. J

    Holes

    :?: :?: :?: Hi Guys, I would appreciated some comments from the Pros please? Thanks, JC
  4. J

    Holes

    Hi, I have my plumbing first fix in and the plumbers joist holes for the rads start at only 400mm from the joist end. The span is 4400mm which makes the minimum 1100mm by building regs (.25-span). This plumbing first fix was inspected and past by building control. Is this common practice for...
  5. J

    Need Power Socket to Loft

    :) Good link Coljack, a couple of those will do a treat in my cut roof, is the maintained version any good as well? JC
  6. J

    Cable routes

    :?: So, I could run this through the ensuite as long as the conduit runs the length of the ensuite (below the bath top) and is visible if the bath is removed? Would 20mm PVC conduit or PVC trunking be allowed? :roll: JC
  7. J

    Cable routes

    Thanks RF and Coljack, Down from Bedroom1 sockets, through joists of ensuite and back up to sockets in Bedroom 2 then it is! :wink: Cheers, JC
  8. J

    Cable routes

    Hi Cooljack, I was led to believe that; "Providing that the space under the bath cannot be accessed without using tools (i.e. screwdriver etc), that space is considered to be 'out of scope'." Would this be not true in the sense that the wall in mention is covered by the bath height...
  9. J

    Cable routes

    Sorry RF, I could have been explained a little better! What i was trying to say is that the ring main cable would be concealed within the blockwork and covered by plaster and tiles in the ensuite, and the accessory boxes are only in bedroom 1 and 2. This would make the cabling a little...
  10. J

    Cable routes

    Thanks for your replies, :D The reason I asked this is that the joists ends run into a 12m wall with 2 steels as well. There are 2 Rads going in as well and the run will be behind one of these. I will be chasing out but was only going to do this where the ensuite runs between the bedrooms and...
  11. J

    Cable routes

    Hi Guys, I have read through the 16thEd onsite guide (Fun not) to see if a ring main can be run horizontally around the room? and all it says on P53 is(no protection required) for Horizontally, vertically to an accessory box or within 150mm from angle formed by two walls or ceiling. Does this...