Recent content by JF77

  1. J

    B&Q fabienne toilet push button.

    Can someone show me how the push button assembly goes together. My son pushed it thru and it separated in to its pieces but I cant figure out how it goes together. Thanks Julian
  2. J

    Back solo 3 60 pf

    Without sounding rude what's the point of this forum then if not to ask for advice? Although I understand anyone's reluctance to help in such a combustible subject. The terms 'competent' and 'engineer' can be misleading.
  3. J

    Back solo 3 60 pf

    ive been having issues with the above. It wouldn't start and occasionally blew the 3 amp fuse and the fast blow on the PCB. I've check the pump, pressure switch and fan. I disconnected each connectors one by one to the PCB and couldn't find the fault. I assumed hat it must be the PCB itself...
  4. J

    Central Heating Staying on Full

    Winter is coming.....so the heating is on and ......same problem!
  5. J

    Central Heating Staying on Full

    Thanks for all the help. I changed the thermistor (thermostat sensor) I got a Honeywell replacement. If I disconnect the thermostat sensor would the boiler still fire? I will check the resistance with the meter. The boiler is in the garage so doesn't get that cold. The 3 way valve is a...
  6. J

    Central Heating Staying on Full

    I've now changed the PCB and the (intermittent) problem still persists. I'm running out of ideas.
  7. J

    Central Heating Staying on Full

    At first I though it was the motorised valve because I'd had problems and replaced it. As soon as I realised there was no call I suspected the pcb. As an ex glow worm apprentice I know how temperamental these are. It's a solo 3 at 16 years old I'm now wondering if it's time to replace it...
  8. J

    Central Heating Staying on Full

    Sorry thought I'd said earlier! its a baxi solo 60pf
  9. J

    Central Heating Staying on Full

    I replaced the thermister before christmas and everything seemed fine. But this week it stuck on again. I've noticed that when its stuck on there is no far left light on the boiler panel Boiler On i.e. no call for the boiler. Which makes me think its the PCB (again! I'm on my 4th) and yes it...
  10. J

    Central Heating Staying on Full

    That would make sense. Before i start looking does anyone know where it could be? Also the water is getting so hot and the tank stat makes no difference and imrecently replaced it. I did my apprenticeship at Glow Worm so im determined to fixit!
  11. J

    Central Heating Staying on Full

    No frost stat.
  12. J

    Central Heating Staying on Full

    Yes I have a multi meter. Which wiring? Behind the programmer?
  13. J

    Central Heating Staying on Full

    I have a central heating system with a convential Baxi power flue boiler (not combi) with a Programmer control, room stat, three way diverter value, hot water tank etc. Every so often the heating sticks on full. Turning the heating off at the controller and/or turnig the stat down does not...
  14. J

    underfloor heating controller

    Can you tell me if the AUBE TH232-A-F-AF controller is a direct replacement for the eStat762 controller? They look the same and have the same specs but one is half the price of the other. (Aube £45/eSTAT £90) AUBE is part of Honeywell so it's made by a repretable company. Julian
  15. J

    boiler sticking on (again)

    OK, the heating stuck on again last night. Turned the boiler off and let the pump over run. Then I turned the hot water on and the 3 way valve moved to the bottom and the boiler fired up left this until it tank stat clicked off. Then turned the heating on and the valve moved to the bottom...