Recent content by John1Mercer

  1. J

    sandtoft 20/20 interlocking tiles help

    Hi, I am the technical Manager at Sandtoft and we spotted your request for info on our 20/20 roof tiles. Firstly, your other replies are correct - you must set the fascia height so that the first course sits at the same angle as the subsequent courses. Also, you must remember that if the roof...
  2. J

    sandtoft 20 20 tiles headlap

    Your best option at 21 degrees is to increase the headlap to 100mm. Chances are the tiles will be fine at 75mm but if you feel the roof is in a exposed area then it is best to err on the side of safety. The amount and type of fixings depends also on how exposed the roof is - and on a number of...
  3. J

    Sandtoft Pantiles - Cloaked Verges

    I picked up your topic on Google alerts. I am the technical Manager at Sandtoft and I can say I agree with the other comments. There is no excuse for leaving the cloaked verges overhanging like that. The roofer should have set the roof out so that the gap is distributed betwen both verges...