Recent content by keepo

  1. K

    Glowworm Micron 60ff - Non Volatile Lockout

    Was suggested on another site to check the pump direction - AND The motor was indeed on the wrong way around. Its been like that since 2018 but has obviously got by - I just went out and swapped it round (wasn't a difficult job and no wiring as just needed to tumble it over). Now either I've...
  2. K

    Glowworm Micron 60ff - Non Volatile Lockout

    Thanks Ian - but when I remove the vent plug and jam in a screwdriver I can stop the pump, but it takes some effort
  3. K

    Glowworm Micron 60ff - Non Volatile Lockout

    It is very much hotter, it gets hot as soon as boiler starts up and too hot to hold quite quickly. The pump and pumped feed I can hold all day long. I have an air vent above each of the Feed and Return pipes, I've opened both separate and let water bleed through for a few minutes each. Still got...
  4. K

    Glowworm Micron 60ff - Non Volatile Lockout

    just discovered that the pumped flow pipe is cooler than the return flow pipe, by quite a bit? Is that significant, I'd have expected the reverse of course
  5. K

    Glowworm Micron 60ff - Non Volatile Lockout

    Made a vid - here is the link
  6. K

    Glowworm Micron 60ff - Non Volatile Lockout

    Ok tried that now - Water flows freely from upstairs radiators. I've just taken a video of it along with a (cheapo) temperature gun on all the pipework around the boiler. I'll try and get it on Youtube and post a link. This time I told system to only feed radiators (to exclude the hot water...
  7. K

    Glowworm Micron 60ff - Non Volatile Lockout

    It has a little tank in the loft to keep it topped up. Heres a pic (and I left a little something for your mate Agile...)
  8. K

    Glowworm Micron 60ff - Non Volatile Lockout

    Thanks - Could you elaborate a bit please (I haven't moved any settings prior to this happening, although the variable knob does turn off the boiler ok). Also, this has happened from working perfectly, to not working in a single day - it has not been a gradual process
  9. K

    Glowworm Micron 60ff - Non Volatile Lockout

    Hi - Can you help? I have a Glowworm Micron FF60 Boiler and it has gone into "Non Volatile Lockout" - Reset light is solid green, boiler and everything restarts after turning off the temp dial and back on again. The fans work, it produces heated water, the pump is spinning (albeit its pretty...
  10. K

    Glowworm Micron 60FF wont start fan comes on for few seconds

    I know, hilarious this bit. As its pretty contentious I'm going to clear this up. The old board had Neon's The new board had LED's As its an old bit of kit, it could have been either it would seem, if the board had been changed because they are all crap etc etc etc Hope this helps...
  11. K

    Glowworm Micron 60FF wont start fan comes on for few seconds

    ....I suppose its like you asking me why your car is misfiring. Could be anything really. But, with some helpful questionning here and there, bit of descriptive background as to when it happens and hey presto - you "guess" right the problem. Its a pretty simple piece of kit really, a boiler -...
  12. K

    Glowworm Micron 60FF wont start fan comes on for few seconds

    Nope - its a micron. I'm confusing Led's with neons, like hoovers and vacuums to me!
  13. K

    Glowworm Micron 60FF wont start fan comes on for few seconds

    Just to finish this off with resolution - it was the pcb board in the end. The board that arrived looked very different from my old board - my original was pretty busy with relays and shedloads of transistors. The replacement had a few chips on it and pretty much nothing else - all plugs were...
  14. K

    Glowworm Micron 60FF wont start fan comes on for few seconds

    Thanks Tony, I'm getting some conflicting info regarding the PCB number. I ordered one by model, but now I've looked at picture, and removed mine, I can see significant difference. Mine has lots more on the board, but same number of plugs. Did they modify these, the model purchased is for a...
  15. K

    Glowworm Micron 60FF wont start fan comes on for few seconds

    Ok ta - Just found one on Ebay and close enough to collect - looks simple enough to change and nothing gas side so I'll give it a go. I'll report back with results...positive I hope!
Back
Top