    Vokera Excell 80sp - Burner problem

    Thanks for the response. I have had another look and it was the push rod for the boiler flow switch not returning to the correct position. Switch was constantly on. With that fixed I can now concentrate on getting advice for the other problem. Both hot water and CH cuts of when temperature...
  2. K

    Vokera Excell 80sp - Burner problem

    I have disconnected the DHW microswitch completly yet it still fires up when it feels like it. Another thing i have noticed is when you first switch the power on to the boiler the fan is on. It might just be slow speed not sure, But also there is a click from the solenoid. Should there be 240v...
  3. K

    Vokera Excell 80sp - Burner problem

    Hi All, I realise this has probably been covered before but all the posts I have read dont seem to be quite the same. Problem - Vokera Excell 80sp The burner wont come on.Although occasionally it will come on go to about 80deg then cut out. Once I have tried and given up and the...