    Grant Vortex Condensing Combi 26 - (2006)

    There are 2 non return valves one in CH direction and one in DHW direction (pump is next in line), turned boiler off, isolated cold mains feed and ran tap, tap stopped. (so I assume its not stuck open!) Also rechecked flow switch by disconnecting, DHW pump carries on running.
  2. K

    Grant Vortex Condensing Combi 26 - (2006)

    Hot water is working fine, keeps water store to correct temperature and burner stops but DHW pump carries on constantly. Therefore no heating.
  3. K

    Grant Vortex Condensing Combi 26 - (2006)

    Hi, its a Grant Vortex Condensing Combi 26 (2006/2007 year) Flow switch checks out fine. Pressure switch checks out fine. Both thermistors checked out fine. Blend valve removed and refitted (hardly any limescale) Since then I found a relay which controls the DHW pump had burn mark around...
  4. K

    Grant Vortex Condensing Combi 26 - (2006)

    Calling all Grant experts please! Just moved to a house with a Grant Vortex Condensing Combi 26 (2006) with full underfloor heating. The plot so far: All was happy until cranking the heating up to 27 degrees, next day no hot water. Figured out if the heating was calling for heat the hot water...