Having run the system for a few day the only comment I would add is setting the stat at 30c was much to low and was acting as a heat sink at night when the fire died down causing the tanks to cool down to much over night. Setting the stat to 60-70C solved the problem. :D
Just to let you know I wired up the pipe stat as Ian suggested placed it 450mm away from the Morso and every thing is now working fine. Again thank you Ian. :D
Thank you all for your help. I think Ians solution my be my best bet, I had thought about it but was not sure if it was safe to do. I'll give it a go. Thank you. :D
Agile,
Pump is on the return.
There is no rad, but it is a big house and the wood burner goes into 4 normal sized domestic water tanks piped in parallel and is not the main source of heating the water just a helping hand, so to speak.
The tank is plastic but is not getting excessively...
Hi all, I have a wood burning stove with a back boiler piped to heat a vented, indirect hot water tank, 28mm pipe work.this was meant to be a gravity system but because of the way it was routed it did not work. I have now fitted a pump which works fine. I want to fit a pipe stat to stop the pump...
Hi I want to restrict the flow on my pumped multi fuel back boiler system, is there a preference as to which gate valve I close, on the flow or return side of the pump. Thanks.