    Madrab replied to the thread Replacing radiator side panels?.
    Situation with Stelrads - delivered with munted side and top grilles - had replacement ones out next day delivery. Guess you get what...
  • Madrab
    In most domestic settings 15mm pipe can flow more than enough if the mains dynamic flow and pressure is available to maintain it, that's...
  • Madrab
    Check flow and pressure at the mdpe. Get water supplier to check pressure and flow rate at their stop tap.
  • Madrab
    Depends on use/required workload. Non storage Instantaneous heaters can be very low flow, that reduces in winter as the mains water temp...
  • Madrab
    Madrab replied to the thread Liquid lockthread instead of PTFE.
    I've used PTFE tape all my days - gas tape as that's what I carry all the time it allows less to be used as it's thicker - without...
  • Madrab
    Madrab reacted to Daveydub's post in the thread Warm water in loft tanks with Like Like.
    And of course any shower valve or blending valve
  • Madrab
    Madrab reacted to dilalio's post in the thread 2 problem rads with Like Like.
    One pipe is near, the other further away Father Dougle! ;)
  • Madrab
    Madrab replied to the thread Warm water in loft tanks.
    Absolutely not - If the cold feed is warming up and expanding back up into the cold water cistern (CWSC) then I'd be checking out the...
  • Madrab
    Madrab replied to the thread 7 bar static pressure.
    An EV or shock arrestor could be used if there is excessive water hammer but if you get the pressure down to a manageable level then a...
  • Madrab
    Madrab replied to the thread 2 problem rads.
    :LOL: :ROFLMAO::LOL: Is it not a really small cow Ted
  • Madrab
    Madrab replied to the thread 2 problem rads.
    Is that Microbore - 10mm - or is it just the perspective of the pic?
  • Madrab
    Madrab replied to the thread 7 bar static pressure.
    Anything over 4bar dynamic can start to affect fittings and valves, increasing wear. I am slightly confused by the large difference...
  • Madrab
    Madrab replied to the thread Leaking HW Cylinder Flange.
    Nope, never found any kind of sealant to work when trying to seal water systems. Is it the actual tapping in the cylinder or the...
  • Madrab
    Madrab replied to the thread PTFE tape or Liquid?.
    +1 for tape, what I've always used so no need to change IMO. As suggested, tape around the olive in a compression fitting only if...
  • Madrab
    Madrab replied to the thread How to remove it.
    Some of these work where the wall disk is captured when the overhead tube is tightened into the wall plate elbow.