    Madrab replied to the thread MDPE Protection.
    You can get specific insulated ducts for every size of MDPE. Shallowduct is the one I used to use for 25/30mm MDPE, from the same people...
    • 1764109955625.png
    • 1764110137623.png
  • Madrab
    Madrab replied to the thread UFH mixer valve pin replacement.
    That's a contact temp sensing head - not a TRV (thermostatic radiator valve) though they do work in the same way. The vial sits inside...
  • Madrab
    Madrab reacted to Exedon's post in the thread What is this bit that's leaking? (Baxi) with Thanks Thanks.
    As suggested try cleaning up a bit Looking at age of pipework that may just be a spring loaded safety valve covered in crud.
  • Madrab
    Madrab reacted to gas112's post in the thread What is this bit that's leaking? (Baxi) with Thanks Thanks.
    its an old fashioned safety valve from the 60/70`s under all that crude are relief holes it can be taken out and plugged off as they are...
  • Madrab
    Madrab replied to the thread Stixall Vs CT1.
    Water sealing what? Neither of them are a standard silicone which would be used for standard sealing, like baths, showers etc, they are...
  • Madrab
    Madrab replied to the thread MDPE Protection.
    Min trench depth in 750mm. Entry point into a property needs to be ducted, insulated and screened. As suggested there are other options...
  • Madrab
    Madrab reacted to Exedon's post in the thread MDPE Protection with Like Like.
    We use the INSUduct system to bring water services into buildings less digging and ducting. I'd be looking to take pipework tight...
  • Madrab
    Get a wire brush and clean it up to have a proper look but it does look like a male coupler into a 3/4" adapting tee. The tee may have...
  • Madrab
    Madrab replied to the thread Washing machine hose....
    If the appliance is located say in a flat etc then they can be handy as they obviously have the double barrier to avoid flooding. As...
  • Madrab
    Madrab reacted to denso13's post in the thread Washing machine hose... with Like Like.
    A good quality normal hose will be fine, hot or cold. You want a bit of air getting into the standpipe, maybe need to trim the hose end...
  • Madrab
    Madrab replied to the thread Low pressure on shower.
    No need to change the pressure on the boiler, this has nothing to do with water pressure, that's just the CH system pressure. The rads...
  • Madrab
    Madrab replied to the thread Isolation valves for heating.
    ISO valves designed for (edit) hot and cold water aren't normally a standard for use in CH systems and TBH there isn't really any...
  • Madrab
    The pump might be getting a little lazy if it's an old boiler and that'll mean the system probably needs balanced.
  • Madrab
    Pic?
  • Madrab
    Madrab replied to the thread setting flow rates on ufh.
    You need to know the pipe spacing as it has been set out and the size of pipe, that coupled with flow/return temps. There are BS EN...
    • 1763900800627.png