Madrab's latest activity

  • Madrab
    78mm height for the Marley appliance adapter, the McAlpine is similar @78.5mm so should fit ok.
  • Madrab
    Kudos do a tray called the connect 2 that allows for multiple connect configurations. Not sure if that might work...
  • Madrab
    Madrab replied to the thread Has Hep2o changed since 2013?.
    If they look like this then no they haven't changed. HEP are known to be stubborn sometimes though when trying to demount and can...
    • 1775305784372.png
  • Madrab
    Madrab replied to the thread Soil pipe connections.
    +1 - that underground coupler wont sit/seal on the cast properly, you need a tight joint, Fernco/flexiseal is the one for that. Clean...
  • Madrab
    Madrab reacted to polesapart's post in the thread Soil pipe connections with Like Like.
    Fernco coupling rather than the brown socket.
  • Madrab
    Madrab replied to the thread Gas Meter and boiler pipe sizing.
    Unfortunately it's not one for the forum, we have no idea what the current pipe sizing is, how much of the current pipe is 22mm and how...
  • Madrab
    No, a trap wouldn't affect whether the pipe would back up or not, either the pipe's restricted, the drain hose isn't far enough in or...
  • Madrab
    You now want to waterproof the whole section, how that's done is up to you. Yes, the Mapei kit could probably do it but it all depnds on...
  • Madrab
    Madrab reacted to drives's post in the thread Annoying shower leak with Like Like.
    If you follow the usual advice of not sealing on the inside of that vertical profile trim, how will it not leak? If as step one you do...
  • Madrab
    Madrab replied to the thread Annoying shower leak.
    That tray isn't sealed properly between the tray and tile on the outside, at the blue arrow, hope that isn't indicative of the tray to...
  • Madrab
    Madrab replied to the thread Help with this fixing!.
    +1 - they are the old standard JG fittings, they have exactly the same end as the current stop ends, tap/valve ends and flexi pipes etc...
    • 1774731482546.png
  • Madrab
    Madrab reacted to denso13's post in the thread Help with this fixing! with Like Like.
    No locking collar on the older fittings like yours.
  • Madrab
    Madrab replied to the thread Help with this fixing!.
    They are old JG pushfit and that's exactly how you release them. Push in the white collar, the trouble is those one tend to become very...
  • Madrab
    Madrab replied to the thread Boiler Issues.
    Not sure why he said that. All boiler's should be fed by a common mains supply. I would suspect that the fused switched unit beside the...
  • Madrab
    Madrab replied to the thread UFH how to change blending valve.
    Are both manifolds serviced by the same Blending valve and pump assembly? Normally there would be one for each. You will need to...