Jo, thanks for all your help on this one.
Luckily I have been able to get the Shock Analyser Board into the new smaller panel. I was able to slot it in sideways down the left hand side using some double sided tape to keep it in place. After re-connecting all the wires back up to the new...
Jo, it's 4 core. I managed to carefully open the sensors this afternoon and have now mapped the wiring out.
Basically from the panel it goes out to the first Aritech 610 shock sensor via a 4 core cable then from there a short 4 core cable goes off to the second Aritech 610 sensor and from that...
Yes Jo there are 3 x 6 core cables in main panel that go to three separate locations but the cable marked REAR has 1 x door contact and 2 x shock sensors on it. Isolating the other two locations is easy enough but I need to see how the sensors on EXIT cable are wired up together, assuming...
So now I know what that little black box is, a Shock Analyser Board, I've been looking at what's wired into it and at present on the sensor loop I have 1 x shock sensor on the cable labelled HALL, 1 x shock sensor on the cable labelled LOUNGE and 2 x shock sensors and 1 x door contact coming...
Thanks for the speedy response, much appreciated.
I thought that box was something to do with the shock sensors.
I plan to just update the box to Optima Gen 4 panel with an onboard keypad and replace the bellbox with a newer compatible one.
Hi
I'm looking to replace my Optima XM alarm panel with a newer one and have been mapping out the existing wires. Everything maps out good, I can see the tamper circuit in place but I have some shock sensors which seem to be wired to a little black box within the Optima XM which doesn't appear...