Recent content by mike3671

  1. M

    Ariston Eurocombi Hot water slow to fire up

    It's totally given up now. The pin that activates the microswitch for the hot water is not moving. I have ordered a new diaphragm and fingers crossed that should fix it
  2. M

    Ariston Eurocombi Hot water slow to fire up

    PS I forgot to add that sometimes when its being particularly stubborn and not firing up at all, if I run the central heating for a minute then I find the hot water will work OK .
  3. M

    Ariston Eurocombi Hot water slow to fire up

    Hi I have and A23 Eurocombi. The water is slow to fire up. I've had look at the assembly where the flow switch is and it seems that the pin on the right hand side that comes out to activate the microswitch is moving very slow. Is it just likely to be a case of whipping that side of the...
  4. M

    Ariston Eurocombi HW problem

    Hi We have just moved into our new house and it has an Ariston Eurocombi(its either an A/23 or A/27 MFFI) We had a problem with the hot water not staying constantly hot. I have read through the manuals and checked online and thought I would try the adjusting the flow rate.I have managed...
Back