    mjtefc9 replied to the thread Shed Base.
    Storage and a workshop.. I will eventually be insulate the walls and roof
  • M
    mjtefc9 reacted to Odds's post in the thread Shed Base with Thanks Thanks.
    What are you using the shed for if you're going to insulate the floor?
  • M
    mjtefc9 replied to the thread Shed Base.
    I’m building the shed from scratch so wanted to insulate the shed base underneath whilst I have the chance.
  • M
    mjtefc9 reacted to Wayners's post in the thread Shed Base with Thanks Thanks.
    I used adjustable feet. The round ones... I made a frame with the adjustable feet and placed shed on that. Why insulate floor? If you...
  • M
    mjtefc9 posted the thread Shed Base in In the Garden.
    Hi all, Building a new shed I’ve got the slabs laid, and I’ve bought some plastic base to raise it off the ground which I’ll screw to...
  • M
    mjtefc9 reacted to plugwash's post in the thread Shed Termination with Thanks Thanks.
    My preffered option would be to have the SWA come up through the floor and terminate inside. Failing that, PVC conduit through the wall...
  • M
    mjtefc9 replied to the thread Shed Termination.
    Thats the issue.. the conductors going through the wall are now singles.. I think I'll just run some flex from the new DB
  • M
    mjtefc9 reacted to justigator's post in the thread Shed Termination with Thanks Thanks.
    Can't you strip a good bit - say 300mm or so - of the armour off the SWA, then just fix the SWA to an external box with a gland and feed...
  • M
    mjtefc9 replied to the thread Shed Termination.
    Brilliant thanks John..
  • M
    mjtefc9 reacted to JohnW2's post in the thread Shed Termination with Thanks Thanks.
    There's no feal reason why not - the terminals of a socket are, in the sense we are talking about, no different from those of any...
  • M
    mjtefc9 replied to the thread Shed Termination.
    Brilliant.. I have a socket currently and was going to replace with an adaptable box.. so maybe no need too now !
  • M
    mjtefc9 reacted to ericmark's post in the thread Shed Termination with Thanks Thanks.
    Most sockets will take two 6 mm² at least MK say they will, but it was just a suggestion, it in my case saved having a hole in the floor...
  • M
    mjtefc9 replied to the thread Shed Termination.
    I get you.. Just didn't think it good practice.. in my situation the socket would have 6mm in and out..
  • M
    mjtefc9 reacted to jj4091's post in the thread Shed Termination with Thanks Thanks.
    It's just the sockets for the plug pins that would be limited to 13A not the terminals for the wires.
  • M
    mjtefc9 replied to the thread Shed Termination.
    But with it being terminated in a 13a socket then extended to the shed ?