Recent content by mtrekker

  1. M

    Beninca Bull8 not responding to remote

    So, to disable photocells one needs to bridge terminals COM and PHC. Controller is operating as expected now without photocell safety feature. Blue wire is the bridge on screenshot.
  2. M

    Beninca Bull8 not responding to remote

    Still looking the way to rule out the photocell. What do I need to bypass to be able to run gate controller without photocell ?
  3. M

    Beninca Bull8 not responding to remote

    When I opened the TX photocell cover then I did notice some water damage. I even used the F-02 flux remover to clean the PCB. Is there a way to "disconnect" the photocells and use the gate controller without photocells, does controller need to be reprogrammed ? Want to eliminate the faulty...
  4. M

    Beninca Bull8 not responding to remote

    Looks like voltage is OK ? Faulty photocell(s) ?
  5. M

    Beninca Bull8 not responding to remote

    I did remove fuses for testing with multimeter. Checked voltages on TX and RX, attached files with readings.
  6. M

    Beninca Bull8 not responding to remote

    Verified, both fuses (F2 and F1) are OK. What I did not understand was the sign "I" on LCD. Is it some status code ? Photocells were producing clicking sound previously, but not any more. Photocell positions have not changed.
  7. M

    Beninca Bull8 not responding to remote

    I have a Beninca BULL8 OM.S and it stopped responding to remote control. LED indicator shows "I". Photocells are not making any "click" sound when waving hand in front of the photocell. Any directions how to trobleshoot ?