    Valiant Turbomax VUW 282 E - Hot Water

    wow 30 yrs is a good run, sounds to me like your diaphragm needs replacing in the diverter, you can buy a diverter repair kit for around 10-15 pound, pretty straight forward to replace if you know what your doing, would def look at replacing now though as your only throwing good money after bad...
  2. M

    Sitting programmer/stat

    So left in the bedroom it would be affected by the towel rail ? so lets move it to the landing where there is no heat source, Hmmmm clever, while the landing is cold the rest of the house where you spend all your time is bloody cooking :(
  3. M

    Sitting programmer/stat

    Thats the idea mate, if the rest of the radiators in the house have been sized correctly (which I doubt very much) then they should heat up at the same rate as the bedroom and once the bedroom is at the correct set temperature then the rest of the house should be too, unfortunately not many...
  4. M

    Sitting programmer/stat

    Vaillant 618 has a built in bypass so no external bypass required, plus building regs require trv's to be fitted in all living spaces, ie bedrooms and living rooms except where your room thermostat is located
  5. M

    Soil Stack

    as long as your AAV is above flood level then your ok, so above the height of your basin which is generally the highest waste point.