Recent content by NathSB

  1. N

    eurosec/risco cpx

    http://www.sentrysecurity.co.uk/security_user_downloads.htm I found this site quite useful
  2. N

    Cheap dialer option ?

    i reckon he might as well,doh!!!!!! :roll:
  3. N

    Cheap dialer option ?

    Pyronix do a Vocaliser that has 4 alarm inputs and dials 4 phone numbers, you can also dial into it using mics supplied, It retails for around £130
  4. N

    advice on cctv

    Have a look at something like the Genie 5324V-they have colour daytime with B&w IR night-time illumination, they are also vandal. As for DVRs, concept Pro do a nice 4ch full time recorder with main and spot monitor outputs and can also be networked if necesary
  5. N

    Training and Qualifications

    I agree that if you install an Alarm in YOUR house it can only be YOUR fault if it doesn't work properly. If you supply and fit an Alarm in SOMEONE ELSEs house then it is your problem if it doesn't perform as you have supplied and fitted the alarm incorrectly.
  6. N

    Training and Qualifications

    You need to be registered to be able to supply Certificates for insurance, it's no good installing an Alarm then a week later the place is burgled because guess what, insurance won't pay out and more than likely they'll come knocking on your door for answers!!!!!!!
  7. N

    eurosec/risco cpx

    All zones should be 12hr meaning active when set apart from any dectector violated upon entry which should be set as Entry for first dection point ie door contact and then Access for a PIR in the Hallway(if fitted)
  8. N

    gardtec eurosec cpx

    hi, If i'm right in thinking in the panel you should have SAB TMP =Tamper Return Bell - =Bell Trigger (0VDC GND) Bell + =12VDC supply Strobe - =Strobe - strobe + = Strobe + Each bell box uses slightly different termanology but all basically work the same
  9. N

    help needed

    Hi, There are ways to reset the codes on the panel but it will also default all the settings on your zones back to factory settings. I would suggest talking to a local company who can default and reprogram the panel for you. It's not the sort of thing that can be done on a forum unfortunately...
  10. N

    Training and Qualifications

    Hi, I would suggest getting in contact with SSAIB or NACOSS,they would be able to put you right regarding legal requirements. Anyone can install an intrudeer alarm, it just becomes sticky once insurance companies get involved
  11. N

    Baxi system Boiler with Honeywell ST9400C

    Thanks, i'll re-wire it and let you know Nath
  12. N

    Baxi system Boiler with Honeywell ST9400C

    Hi All, Recently had a new Baxi 28HE Boiler installed which is a vast improvement on my previous non-functioning unit!! My only problem is that I can't get my controller to work it. I've removed the link in the boiler(L out,SW L in) and wired the output from the boiler into the SW L in. The...
Back
Top