  1. N

    Ace High boiler - no CH

    THANK YOU everyone. I've just picked up & installed a reconditioned PCB and the boiler fired into life. I now have hot radiators again. Looking forward to the thermometer in the hall getting back into double figures! Great to know this forum exists and that there are people on it who...
  2. N

    Ace High boiler - no CH

    Doesn't the fact that the burner shuts down after the DHW demand is withdrawn signify that the diaphragm pin is doing it's job?
  3. N

    Ace High boiler - no CH

    I must admit that was what I thought happened - re the diaphragm. Update - I have sourced a reconditioned PCB for £50, so picking that up tomorrow. I'm convinced it's control related. The diverter valve keeps being mentioned.. what other names would that be known as? I can't see diverter...
  4. N

    Ace High boiler - no CH

    Slugbaby - thanks - that's actually the manual I have here and have been working to. Meldrewsmate - that's really interesting... would that be the the bolt that the diaphragm pin does through? I have to hold my hand up and say I only replaced the plastic and rubber parts. <slaps head>...
  5. N

    Ace High boiler - no CH

    Thanks mandate - sadly that's a dead link & I can't seem to find that pdf on their site. Maybe its been taken down?
  6. N

    Ace High boiler - no CH

    Hi all - newbie here with a problem... Today I replaced the diaphragm on my Halstead Ace High combi boiler. All went well, I now have hot water again. It's the second time in 10 years I've done this, so not a virgin to the (non gas) side of the boiler. HOWEVER - I now have no CH. The CH...