Recent content by nitram76

  1. N

    Danfoss RX1 wiring

    Thanks for that but after a bit of head scratching I've got it working now. Used L and N from boiler L2 & N. Removed link in boiler and wired L3 to terminal 3 on the RX1 and linked terminal 2 to L. Works a treat!
  2. N

    Danfoss RX1 wiring

    Thanks but I'm still confused, sorry if I'm being stupid but you say connect L1 where the link was to L? (240v mains) That doesn't seem right to me. I get the 240v supply bit and that the L1-L3 link is where I'm wiring in the boiler but the RX1 control end is where I'm confused. See top of...
  3. N

    Danfoss RX1 wiring

    I've got a Danfoss TP700 and I'm connecting the RX1 receiver up to a Halstead Ace. The boiler has terminals L1 and L3 linked as it's running on the timeclock. The RX1 has L & N supply and terminal 2 as a common with 3 and 4 zone on and off. It says to connect pin 2 to mains live but I don't...
  4. N

    Halstead ace DHW problem

    Thanks. How much are they then? And How easy is it to do myself?
  5. N

    Halstead ace DHW problem

    I've got a problem with lukewarm water on my Halstead ace. The CH works fine but the CH pipes get hot when I turn the hot water on. Looking at the pins on the diverter they both operate when the hot tap is turned on and they both return when it is turned off. The CH pins operates fine for...
  6. N

    Halstead Ace DHW only just warm

    I've got a Halstead Ace which has started producing only warm water instead of the scalding hot it used to. The CH works fine and the DHW is hotter when the CH has been on. The CH flow pipe is also red hot when I switch the tap on. Is this the diverter valve as I suspect and if so, how...
Back
Top