Recent content by P88sty

  1. P

    Baxi 105e Combi - Fires up but no Hot Water - Arrgghhh

    Just to advise the British Gas guy came out yesterday, they do a £99 "fix any fault" deal providing you sign up on a 12 month maintenance contract at £20 a month. this was my best option considering the cheapest i could get the exchanger (providing this was the fault) was £110 without fitting...
  2. P

    Baxi 105e Combi - Fires up but no Hot Water - Arrgghhh

    Q:do the rads heat up when the HW is on? If so the diverter could be leaking/passing a bit A:The Rads do heat up when the HW is on Q:What's the flow of the hot water, is it fast / slow? Does the fault happen when the flow is very high ? A:The Flow is fine (fast) and regardless of what the...
  3. P

    Baxi 105e Combi - Fires up but no Hot Water - Arrgghhh

    Q:when the water goes lukewarm is the boiler still on for H/w demand? A:Yes Q:after the hot water going lukewarm, does it soon go hot as normal again, like a pattern? A:Sometimes we will eventualy get hot water, but in the main it remains luke warm
  4. P

    Baxi 105e Combi - Fires up but no Hot Water - Arrgghhh

    Hi Guys, been reading a lot on here about the 105e not firing up when hot water is in demand, and the main culbrit being either the DHW flow switch or diaphragm. wondered if someone could advise on my scenario. Turn on Hot water, metal pin pops out of both diaphragm bits located bottom left...