    Worcester BF 240 Combi CH Fault

    Afternoon RESULT. Replaced the CH return thermister with a new one and it seems to have done the trick. No relay flickering, just seamless heating 'till the room stat switches off. Steve
  2. P

    Worcester BF 240 Combi CH Fault

    Afternoon I've just tested the resistance of the CH return sensor and found it to be within limits but then found one of the rivet-fitted spades was loose. When the wires to it were moved, tester showed open cicuit. I've just dabbed some solder onto it and it appears now to be OK! Do any of you...
  3. P

    Worcester BF 240 Combi CH Fault

    Tony Thanks indeed for your swift response. It's a bit technical for me but I can find my way around most things. I've sat and watched it and studied the electrical diagrams for hours and would like to pin it down firmly before I start spending on it, the current economic climate being what...
  4. P

    Worcester BF 240 Combi CH Fault

    Mornin' All I have a 240 BF which has an intermittant fault with CH.The relay on the driver board which switches the gas valve on/off flickers rapidly, causing the burner to flare-up repeatedly but not stay lit. It works perfectly with hot water, so I reckon it's something specific to the...