Recent content by Peter Saunders

  1. P

    Vaillant Tuebomax VUW GB 242 /1E

    Hi aris, Hope you have sorted it out already. But if not, Yes after the demand for water had stoped the light would start flashing and would be constant. only a reset would start the boiler. apparently there is a timing issue also with the switch. If the small white plunger that sits on top...
  2. P

    Vaillant Tuebomax VUW GB 242 /1E

    Yes sorry about the spelling. That one got past me. It is nice and warm not underground. Is it usual for a such a large deposit to build up. Bengasman. Could you explain the sooner rather than later quote as I am starting to get a bit worried. Should I expect more problems as to this...
  3. P

    Vaillant Tuebomax VUW GB 242 /1E

    Hi Tony, Corgi territory is a rocky place to tread. But thanks anyway. I banged about on the net and spoke to Vaillant and with much staring at the boiler everything seamed to point to the Pressure Differential Switch. So I changed it this morning and so far so good. I had a look inside the...
  4. P

    Vaillant Tuebomax VUW GB 242 /1E

    Hi all, I have a vaillant Turbomax VUW GB 242 /1E. And it keeps failing the diagnostic panel shows the yellow ignition indicator light flashing. The boiler then won’t work not for heating or water. I have to reset the boiler at the switch and then it fires up as normal runs until the...