I own a small 3 bed detached house built in the late 60s, the ground floor radiator pipe work drops down from the ceiling in 15mm copper and is surface run to the radiators.
I hate the look of it so my plan is to fit designer radiators and run 10mm plastic chases into the walls.
My plan is...
Hi guys!
I have an NVR sited in my utility room with 4 IP cameras connected into individual ports on the NVR.
I’d like to move the NVR to the lounge so it’s more accessible.
There is already a CAT5 cable between utility room and lounge.
Can I connect the cameras to a router in the utility...
A quick update.
The planning department have emailed me and have said that the pictures I previously sent them don't show the entire building but they agreed that they wont enforce any planning action if I can show them that it was in fact complete.
Luckily I do have pictures so I'll sned...
Thanks for all the replies!
I've done a bit of research and it seems they cannot enforce any lack of planning on the building as long as I can prove that the building is over 4 years old. Luckily I took a lot of pictures during the build and also have invoices for materials which show it was...
Back in 2018 I built a summerhouse, at the time the boundary of my property wasn’t clearly defined but I’m prepared to accept that I built it less than two meters from the boundary.
Back in April of this year I had a card out through my letterbox from the local planning department, I called the...
Hi Chaps
I have bulit a bike shed at home which I have wired for 2 magnetic contacts, 1 dual-tec, RKP and sounders etc.
I was going to use a Veritas R8 panle as they have been around for years and I am familiar with them but I'd quite like to be able to access the system via an app on my phone...
Hi Chaps.
I have a standalone fridge and have noticed that it is getting cooler than 14 degrees c but there is a layer of thick frost on the rear of the top section.
What could be causing it to ice up yet not get cool enough?
Thanks
Got called to a house today with a strange problem, it wouldn’t actually do it when I was there but the customer had recorded to the sound for me.
Symptoms are when the system is unset it randomly makes a two tone sound the same as you get during power failure but then it’s followed a few...
Hi chaps!
Last week I replaced a float valve in a CWS vessel which was passing.
The CWS vessel is located in a bedroom cupboard and the customer is complaining because she can hear it dripping for a couple of hours after she goes to bed.
I popped in to have a look today and it does drip...
Thanks for the advice regarding the smoke!
I’m not sure what make and model the burner is but it’s a Danfoss BFP 11 pump.
I won’t be there until tomorrow night but I will see if I can get any more information.
Thanks again
I have to admit I haven’t really checked anything yet, it’s a strange noise, it whines but the sound undulates regularly so it gets whiter and louder once every couple of seconds.
I’m going to service it this weekend, I do have an oil pressure gauge and a manual which specifies the correct oil...
Hi chaps.
I am an experinced gas boiler engnieer with limited oil boiler experience.
My partner has a oil boiler fitted and it's a little noisy in use, it makes a high which whining noise in operation,.
The noise is definitley not coming from the circulation pump so I suspect it's either motor...