hello its your grandad lol
im only 40 lmao anyway judging from your pics i reckon you could have bent them in but each to there own as for frictional loss, a loss is a loss right and the less joints you have the less likely its going to leak food for thought mate
cheers for the humour...
hi all
i thought of all that, the house is brand new and theres no hot water only switch on the programmer?? she says she gets hot water ether by turning on the heating or by using the emersion heater on the cylinder but without looking at it god knows many thanks to you all for your help if...
hi all
elbows yuk hate them especially push fit , machine bends all the way no joins =no leaks and no frictional loss the way ahead is bend it lol
nice work though mate looks good
hello again
might be a good idea to have your incoming mains altered so there is only one main supplying the whole house since the floor is going to be up anyway just food for thought i hope it all goes well
regards
plumber1722
ps please feel free to look at my facebook page...
hi all
ive just had a look at the regs on page 10.4 its saying that if you soften your supply you have to have an unsoftened tap for drinking direct from the mains so you can have the sink softened but you must have a drinking tap i also had a look at the fliud categories from what i...
the water at your kitchen sink HAS TO BE FRESH POTABLE DRINKING WATER not softend im sure its against water regs to soften it so dont do it if they find out you may get fined alot of money and youll be drinking salted water fit the softner to the main thats feeding the rest of the house and the...
hello
i would say if in doubt fit a double check valve on the copper before the washing machine valve anyway i personally wouldnt trust a push fit so go for a compression fitting one
hope this helps
melting a hole is a very bad idea use a hole saw mate as seen in a previous post it will curl the edges and you need a flush fit same on the cylinder use a hole saw as for the speed of drilling whatever yuo feel confident with but i would start slow at first
hope this helps
Hi all
i have a query i have a customer who has a new build house she cant get hot water without putting the heating on although she does have an emersion heater on the hw cylinder, on the programmer there isnt a switch for hot water only which is what is confusing me is it the case that she...
Hi all
my mate has aquired a honeywell 3 port valve but the job he wants me to do has two honeywell 2 port valves installed one of then is broken and i think its the actuator head thats gone does the head from the 3 port fit on the 2 port if so job done can anyone enlighten me on that
many...